Postgraduate Orthopaedics Viva GuideFRCS (Tr & Orth) Examination
Trauma

Chapter 9 General principles and fracture biomechanics

📄 pp. 485–552 (PDF)Book: Postgraduate Orthopaedics Viva Guide

📝 Reduction summary (~35% shorter) — high-yield viva edition. All figures & classifications retained; key points bolded for speed reading. Source page badges preserved. Full text: postgradviva2026.pages.dev
source p. 486

Introduction#

Fracture biomechanics can be tough-going for most candidates and yet it is definitely an A-list topic.

Textbook chapters can be too complicated and detailed to understand whilst short note sections may appear incomplete as biomechanical assumptions have not

We hope this chapter uncomplicates a difficult area of the syllabus that a lot of candidates find offputing.

source p. 487

Structured oral examination question 1#

source p. 488

IM nail biomechanics

EXAMINER
This is a radiograph of a broken femoral nail that was used to fix a distal femoral shaft fracture (Figure 9.1). How can you prevent nail breakage? CANDIDATE 1 : I would insert the largest diameter solid nail that is available for use.
Figure 9.1
Figure 9.1Figure 9.1 Lateral radiograph of left distal femur demonstrating a broken femoral nail.p. 490
COMMENT
Not a good start. The answer isn’t particularly well thought out and is not scoring the candidate any marks.
EXAMINER
Why would you use a solid nail? Most nails used in orthopaedics are hollow.
CANDIDATE
Because a solid nail will be stronger than a hollow nail. This is continuing on with a poor choice
EXAMINER
What do you mean by the term ‘stronger’?
CANDIDATE
Strong is the ability of a material to resist deformation. This is an incorrect definition and the vi vais going nowhere.
EXAMINER
How does this relate to ultimate tensile strength (UTS)?
COMMENT
Strong is an imprecise biomechanical term. This will then lead onto discussions about area and polar moments of inertia, the biomechanical benefits of using larger-diameter nails for long bone fractures, the solid versus hollow nail dialogue, benefits of IM reaming, etc. Another road to journey down is patient factors that could predispose to nonunion and eventual nail breakage(smoking, alcohol, malnutrition etc) (Score 4.) CANDIDATE 2: An unstable fracture pattern (segmental or comminuted) or the use of a small unreamed diameter nail increases the risk of nail breakage. Early weight bearing with delayed fracture healing increases the time over which cyclic stress may act to cause fatigue failure and nail breakage.
source p. 489

Excessive impaction during nail insertion duet o under-reaming of the medullary canal may also weaken the nail.

Intramedullary nails rarely break when no locking screws are used. Statically locked nails can produce high concentrations of stress at the proximal or distal end of the nail, predisposing it to breakage.

(Score 6.)

EXAMINER
What do you mean by fatigue failure?
CANDIDATE
Failure of a material with repetiv e loading below the ultimate tensile strength.
EXAMINER
What do we mean by S-N curves?
CANDIDATE
An S-N curve gives information about the number of cycles a material can endure for a given stress level.
EXAMINER
Can you drawout an S-N curve?
CANDIDATE
(Figure 9.2)
Figure 9.2
Figure 9.2Figure 9.2 S-N curve.p. 491
EXAMINER
What makes fatigue failure more likely?
CANDIDATE
In the presence of stress risers such as a hole, a sharp edge, an indentation, notch or scratch, the loads
EXAMINER
Why?
CANDIDATE
Crack propagation.
EXAMINER
What do you mean by this?
CANDIDATE
Sorry, I am not sure. Score 6. For a score 8: The applied stress concentrates on residual material beneath a stress riser and means the number of cycles to failure is much lower than the fatigue strength. Using a stainless steel rather than titanium nail (higher Youngs modulus) but long list of pros and cons for each material.
source p. 490
Figure
Figurep. 490

Figure 9.1 Lateral radiograph of left distal femur demonstrating a broken femoral nail.

source p. 491
Figure
Figurep. 491

Figure 9.2 S-N curve.

source p. 492

Structured oral examination question 2#

source p. 493

Area and polar moment of inertia

EXAMINER
What do we mean by the terms second moment area and polar moment of inertia?
CANDIDATE
The further away the material is from the centre of a beam, the greater its bending stiffness. The polar moment of inertia applies to a cylindrical structure and its ability to resist torsion.
EXAMINER
How do the second moment area and polar moment area differ between a solid and a hollow nail?
CANDIDATE
For a solid nail the second moment area or second moment of inertia is directly proportional to the fourth power of the radius. I = π(rO4 – rI4)/4 Nail wall thickness is equal to the difference between r0 = outer radius and r1 = inner radius.
source p. 494

Controversial topic

The assumption that if a nail has a thin wall then the inner radius is roughly equal to the outer radius,

Hollow orthopaedic implants do not approximate to rO3.

In engineering, approximations are made for ‘thin’ cylinders, which is when the inner radius (r1)

approaches the outer radius (r0). The rO4 – rI4 term approaches rO3 as rOrI, hence the approximation.

The wall thickness of a hollow nail must be optimal to be able to withstand bending stress and avoid sudden failing by buckling (local concentrated deformations). The implant also starts behaving as a curved sheet rather than a hollow cylinder .

A Synthes 13 mm nail (6.5 mm radius) has a 1.2 mm wall thickness. r0 = 6.5 mm, rI = 5.3 mm (which is

So (rO4 – rI4) = 1785789 = 996. 996 is 3.6 × 275, so to estimate a hollow nail to rO3 is a 360% underestimate which is quite significant.1

For a solid nail the polar moment of inertia (polar moment area) varies with the fourth power of its radius.

Jo = πr4/2

For a hollow nail the polar moment of inertia varies with the fourth power of the outer radius minus the inner radius.

Jo = π(rO4 – rI4)/2

EXAMINER
Which type of nail, solid or hollow, biomechanically do we prefer to use?
CANDIDATE
A hollow nail is more efficient as less material can be used for equivalent values of bending and torsional rigidity.
EXAMINER
Why?
CANDIDATE
The further the material is spread away from the neutral axis of the nail, the greater
EXAMINER
Why are spiral fractures of the tibia more common in the lower third of the tibia even though the cortex is much thicker there?
CANDIDATE
Under a specific load the lower third segment will deform more than the upper segment of the tibia. The further amate rial is distributed away from the neutral axis of the structure, the greater the polar moment and therefore greater strength and rigidity against torsional stress.

(For score 8 candidates.)

EXAMINER
What about the bending and torsional rigidity of a hollow nail with an open section?
CANDIDATE
Stress is transmift ed uniformly through the entire thickness of the cross-section of a closed-section hollow nail without any change indirection. The reis a change is stress direction in an open nail when its gap is reached with a significant fall in the magnitude of polar moment (Figure 9.3).
Figure 9.3
Figure 9.3Figure 9.3 With the open-section nail the reis reversion of the direction of torsional stress as shown by the arrows. In a closed p. 496
EXAMINER
What about differences between the cross-sectional shape of a nail?
CANDIDATE
A cloverleaf cross-section nail improves torsional and bending rigidity compared to a round cross-section .
EXAMINER
Why?
CANDIDATE
I am not sure.
source p. 496
Figure
Figurep. 496

Figure 9.3 With the open-section nail the reis reversion of the direction of torsional stress as shown by the arrows. In a closed hollow nail, the nail stress lines are in the same direction because of the continuity and therefore the nail is stronger against torsion.

source p. 497

Structured oral examination question 3#

source p. 498

IM nail

EXAMINER
What does the picture show (Figure 9.4)?
Figure 9.4
Figure 9.4Figure 9.4 Titanium IM femoral nail.p. 500
CANDIDATE
This is a clinical picture showing an intramedullary nail. They are usually made of titanium. Be able to describe the typical features of an IM nail.
EXAMINER
How does an IM nail function?
CANDIDATE
IM nails stabilize a fracture by acting as internal splints with load-sharing characteristics.
EXAMINER
What do we mean by an internal splint?
CANDIDATE
Splintage is defined as a construct in which micromotion can occur between bone and implant, providing
EXAMINER
Do nails always act as a load-sharing device?
CANDIDATE
It depends on how it is used. Candidate waffle.
EXAMINER
How is it used?
CANDIDATE
[Silence ...] In more comminuted fracture patterns that are not axially stable, a nail will have to transmit all the forces applied to the limb, so-called load-bearing.
EXAMINER
Which is stiffer, a solid or a hollow nail?
COMMENT
The bending stiffness of a cylindrical cross-section is proportional to the fourth power of its radius as described by the second moment of area. If, however, a constant volume of material is used for construction of an IM nail of fixed length, then the use of a hollow nail would allow a greater outer radius to be used, resulting in a stiffer nail.2
EXAMINER
When plating a fracture what factors do you need to consider?
CANDIDATE
I would need to decide if I want to achieve primary or secondary bone healing.
source p. 499

If the fracture was significantly comminuted I would ideally choose to plate in bridging mode

Simple fractures could be treated with interfragmentary compression.

Ideally, plate position should be on the tension side of the fracture. I would need to decide the length of plate itself, the number and relative position

The plate length should be 2–3 times higher than the overall fracture length in comminuted fractures and 8–10 times higher in simple fractures.

The plate screw density should be kept below a value of 0.5, indicating that less than half of the plate holes are occupied by screws.

Such a construct will fail if one screw breaks due to overload or if the screw loosens, so it is generally advised to add another screw to each side of the fracture construct.

Plating offers two different fixation concepts – splinting and inter fragmentary compression.

Comminuted fractures are best treated using a splinting technique, because local bone and soft tissue de vascularization can be minimized;

When nailing the position, the length and diameter of the nail as well as the position of the locking bolts are more orless

EXAMINER
What is the working length of a plate?
CANDIDATE
The working length of a plate is defined as the distance across a fracture site between the two nearest points
EXAMINER
How is the working length of a plate altered?
CANDIDATE
which increases a plate’s construct stiffness Screws placed further from the fracture site increase the working length and produce a less-stiff construct that permits more motion a t the fracture gap.
EXAMINER
What problems may arise if screws are placed too close to the fracture site?
CANDIDATE
Placing screws further from the fracture site can better distribute the stress the plate experiences and decrease the risk for plate fatigue failure.
source p. 500

The addition of more than three screws per fragment does not significantly impact on a plate’s construct stiffness in axial loading.

EXAMINER
Why do we want to avoid over-torqueing of screws?
CANDIDATE
Over-torqueing of the screws should be avoided during insertion. The screw head can be destroyed.
EXAMINER
What else?
CANDIDATE
As a screw is inserted into bone, the screw head compresses the plate against the bone with a force proportional to the torque applied to the screw. Although pull-out strength is related to the depth of the screw thread and quality of the bone, stripping the screw reduces the pull-out strength of the screw by more than 80%.
EXAMINER
Why do we retighten screws before closure?
CANDIDATE
Before wound closure, all screws should bere tightened to allow time for stress relaxation of the screw–bone interface.
Figure
Figurep. 500

Figure 9.4 Titanium IM femoral nail.

Table 9.1 Characteristics of fixation.

Table rendered from source
Table rendered from sourcep. 500
source p. 501
Table rendered from source
Table rendered from sourcep. 501

Bi cortical

Self-tapping

Self-drilling

Standard cortical

Locking

source p. 502

Structured oral examination question 4#

source p. 503

Biomechanics IM nail

EXAMINER
What is the working length of a nail?
CANDIDATE
More simply, it is the distance between the two points on either side of the fracture where the bone firmly grips the metal. Thus, working length is the unsupported portion of the nail between the two major bone fragments and reflects the length of a nail carrying the majority of the load across the fracture site.
EXAMINER
What is the relationship between the working length of a nail and bending rigidity?
CANDIDATE
The bending rigidity of a nail is inversely proportional to the square of its working length.
EXAMINER
What about torsional rigidity and working length?
CANDIDATE
If all else fails, a shorter working length means the greater the bending and torsional rigidity of a nail, i.e. a stronger fixation.
EXAMINER
What factors affect working length?
CANDIDATE
When the bone bends at the fracture site the nail may become fixed to the bone by 3 point fixation. Type of fracture (fracture pattern) and if the fracture is reduced. Interlocking. Reaming. A nail has a shorter working length inbending with fixation of a transverse fracture than when used to stabilize a comminuted fracture.
EXAMINER
What affects bending rigidity?
CANDIDATE
Bending rigidity is affected by: 1. 2. Structural properties. (a) Length. (b) Second moment area (SMA) of the nail, which is a variable that describes the spatial distribution of amate rial within a structure.

For a solid circular nail, the bending rigidity is proportional to the fourth power of the nail’s radius.

SMA = π.r4/4

For a hollow nail the bending rigidity is very roughly proportional to the third power of the nail diameter.

EXAMINER
Are you sure (see above)?
CANDIDATE
It is more accurate to say the bending rigidity is directly proportional to the fourth power of the outer radius minus the
EXAMINER
What affects torsional rigidity?
CANDIDATE
1. 2. Structural properties. As lofted nail has a torsional rigidity of 1/50 that of a non-sloft ed nail.
EXAMINER
And?
CANDIDATE
A nail with sharp corners or fluted edges resists torsional forces to a greater degree than a smooth-walled nail.
EXAMINER
What is the difference between second area moment and polar moment for a nail?
CANDIDATE
The second moment area and polar moment area represent the relationship between bending and torsional rigidity of a nail and its cross-sectional dimensions. This may lead on to the examiners asking about the differences in second area moment and polar moment for a solid and hollow nail (see above).
EXAMINER
What happens to polar moment of inertia when a nail has a slot?
CANDIDATE
The polar moment of inertia is greatly reduced.
EXAMINER
What about length of the nail, how does that affect bending rigidity?
CANDIDATE
The length of the nail between the forces working to bend it determines the length of the moment arm and
source p. 505
EXAMINER
How is bending and torsional stiffness related to working length?
CANDIDATE
The bending stiffness of a nail is inversely proportional to the square of its working length. The torsional stiffness is inversely proportional to its working length.
EXAMINER
How does medullary reaming affect working length?
CANDIDATE
Medullary reaming prepares a uniform canal and improves nail–bone fixation towards the fracture, thus reducing the nail’s working length.
EXAMINER
What do you mean by stiffness?
CANDIDATE
Stiffness is defined as the slope of the curve in the elastic range on a stress–strain curve.
EXAMINER
Are you sure?
CANDIDATE
Yes. Stiffness is defined as the slope of a force versus displacement graph. Elastic modulus is the corresponding slope, but of a stress versus strain graph.
EXAMINER
What material are IM nails made of?
CANDIDATE
They are made of either titanium or stainless steel. IM nails can be solid or hollow.
EXAMINER
How can we reduce the stiffness of a nail?
CANDIDATE
One way of reducing stiffness ist o put a longitudinal slot in the wall of a nail. Very stiff nails may damage the bone if there is any discrepancy between the shape of the nail and that of the bone.
EXAMINER
What factors alter a nail’s axial, bending and torsional rigidity?
CANDIDATE
This can be divided into material and structural properties Parameters include cross- sectional geometry,
source p. 506

Structured oral examination question 5#

source p. 507

IM nails

Initial questions on area and polar moment of inertia, bending and torsional rigidity (see above).

EXAMINER
How does the presence of a slot affect bending and torsional rigidity of a nail?
CANDIDATE
The presence of a slot reduces both the bending and torsional stiffness of a nail.
EXAMINER
Why do we uses lofted nails?
CANDIDATE
It makes the nail easier to insert.
EXAMINER
What else?
CANDIDATE
Err ... Bone tissue exerts an equal and opposite force on the nail (Newton’s third law). EXAMINER : What about hoop stresses? Sorry? Hoop (expansion) stresses are generated in the bone when an IM nail is inserted. If hoop stresses are too high they can cause comminution or splintering of the bone.
EXAMINER
What is the difference between stiffness and rigidity?
CANDIDATE
[Long silence ...] Sorry, I don’t know. Rigidity and stiffness are very similar concepts often used interchangeably to denote overall performance of a structure. Depends on amate rials stiffness and geometry construct. Rigidity incorporates both the type of material and its shape and size.
EXAMINER
Why do we use interlocking screws (bolts)? What function do the y perform?
CANDIDATE
Interlocking screws help control torsion and axial loads placed on the nail. They provide rotational and longitudinal stability.
EXAMINER
Historically, why were they introduced?
CANDIDATE
The use of interlocking screws expanded the indications for use of IM nails to include more
source p. 508
EXAMINER
What are the disadvantages of using interlocking screws?
CANDIDATE
The holes in the nail act as stress risers. The weakest part of the nail to fatigue is a t or just proximal to the most proximal distal locking screw. There is an increased rate of nail breakage if the fracture is within 5 cm of these screws, or if the screw hole closest to the fracture is left unfilled. The closer the fracture is to the distal locking screws, the less cortical contact the nail has, which leads to increased stress on the locking screws and greater chance of screw breakage.
EXAMINER
When nailing a long bone, how do you decide on how many locking screws to use?
CANDIDATE
The number of interlocking screws used is based on fracture location, amount of fracture comminution, and the fit of the nail within the canal. Midshaft transverse femoral fractures have the greatest fixation stability because of isthmic cortical contact.
EXAMINER
How are locking screws (bolts) different to other screws used for fracture fixation?
CANDIDATE
The screw functions to reduce torsional stresses acting on the nail and is not designed to maximize pull-out strength.
EXAMINER
What may occur if you place too many screws in multiple planes through a nail?
CANDIDATE
An IM nail allows fracture healing with relative stability even if a nail is statically locked. Minor movements occur between the nail and screw even in a static mode of nail fixation.
EXAMINER
What is the biomechanical effect of the orientation of the locking screw?
CANDIDATE
Distally, however, there is litile difference. In the femur, studies suggest no difference in biomechanical behaviour with locking screw orientation.
source p. 509
EXAMINER
What effect does multiple locking screw breakage have on fracture stability?
CANDIDATE
Premature failure of locking screws especially with unstable fracture patterns may lead to angulation shortening, malunion and IM nail migration.
EXAMINER
How can you reduce the risk of locking screw failure?
CANDIDATE
Compared tousing a smaller screw a larger screw diameter increases fatigue resistance. A stainless steel screw has a different fatigue life than a titanium screw. Stainless steel is more ductile than titanium. Inserting a screw incorrectly can result in surface defects as well.
EXAMINER
Why not insert the largest locking bolt possible to reduce the risk of locking bolt failure?
CANDIDATE
The largest diameter of locking bolt that can be used is limited by the diameter of the nail. Nail hole size should not exceed 50% of the nail diameter. Interlocking screws undergo four-point bending loads, with higher screw stresses seen at the most distal locking sites (Figure 9.5).
Figure 9.5
Figure 9.5Figure 9.5 Four-point loading on distal interlocking bolts. Four-point loads (arrows) acting on a distal interlocking screw.p. 509
Figure
Figurep. 509

Figure 9.5 Four-point loading on distal interlocking bolts. Four-point loads (arrows) acting on a distal interlocking screw.

source p. 510

Structured oral examination question 6#

source p. 511

Plates

The candidate is shown a laminated picture of a plate and asked to describe.

EXAMINER
What is this?
COMMENT
This can be difficult to answer without having a pre-structured approach to the question. Think in terms of: 1. 2. Width of plate (small, narrow, broad). 3. Shape of screw holes (round slots, oval slots). 4. Surface contact characteristics (L CP). 5. Intended site of application condylar plate). 6. 7.
EXAMINER
What happens to the moment of inertia if you place a rectangular beam 2 × 4 on its edge rather than on its side?
CANDIDATE
It is ‘stronger’ inbending when placed on its edge (2ʹʹ side) than on its flat (4ʹʹ) side, yet its cross-sectional area remains constant. A 2ʹʹ × 4ʹʹ beam on its edge has an area moment of inertia f our times greater than on its side and thus demonstrates a fourfold increase in rigidity. The practical relevance is that when fixing a fracture, the bone surface chosen to apply a plate can affect mechanical construct stiffness. The bending stiffness of a bone plate is proportional to the thickness of the plate to the third power, whereas the bending stiffness is directly proportional to the width or elastic modulus of the plate. Therefore, changing the plate thickness has more effect upon stiffness than changing the plate width or material. A plate made of one material can have significantly different properties depending on its width, length, thickness and position of holes.

This is expressed as the base (b) times the height or thickness cubed over 12.

Ia = bh3/12

Bending stiffness = EI a, where E is Young’s modulus, Ia second moment of area.

COMMENT
Candidates need to understand how the properties of a plate can change depending on its position on
EXAMINER
If you are plating a humerus fracture when would you use a 3.5-mm or 4.5-mm thickness plate?
CANDIDATE
Therefore, the bending stiffness of a 4.5-mm plate will be more than twice the bending stiffness of a 3.5-mm plate (3.5 = 42,875, 4.5 = 91,125). The 4.5-mm plate is more staggered for screw placement compared to the 3.5-mm plate, which has a narrow area for screw insertion. This reduces the risk of postoperative fracture. The bone shape of the humerus is not flat and not plate-friendly and it can sometimes be difficult to fit a 4.5-mm plate onto the humerus. However, for examination purposes candidates should err on the side of caution and suggest usage of a 4.5-mm plate.
EXAMINER
What causes a bone to break after fracture fixation?
CANDIDATE
There are two mechanisms. That is why some surgeons prefer to leave the last screw hole in a plate empty. This is particularly concerning if the end of the plate is in a high-stress region such as the subtrochanteric part of the femur. In this situation a longer plate should be used to bypass the high-stress area, especially if bone quality is poor.
EXAMINER
What do we mean by working length of a plate?
CANDIDATE
The distance between the proximal and distal screw in closest proximity to the fracture is defined as the ‘working length’ of the plate.
EXAMINER
Why is working length important?
source p. 513
CANDIDATE
Plate working length has been shown to influence construct stiffness, plate strain and cyclic fatigue properties of the plate.
EXAMINER
What are the principles of plate fixation?
CANDIDATE
The principle is the conversion of tensile forces to a compression force on the convex side of an eccentrically loaded bone. This is achieved by placing a tension band (bone plate) across the fracture on the tension (or convex) side of the bone. The plate should be fixed to the tension side of a long bone to avoid fracture gapping. Plate stresses are significantly increased by gapping at the fracture site and may lead to fatigue failure of the plate. Torsional and bending stiffness of a fracture construct can be significantly increased, and therefore, plate strain reduced, by increasing the length of the plate itself.
EXAMINER
What about leaving a fracture gap opposite the plate?
CANDIDATE
As long bones are subjected to eccentric loading, a plate applied to the outer (convex) side counteracts tension forces and provides rigid internal fixation.
EXAMINER
What happens if a plate is applied to the tension cortex, but the opposite cortex is defective?
CANDIDATE
The defective cortex cannot resist compression and the plate will undergo bending stresses and fail under axial load.
EXAMINER
How do plate length and screw number affect the biomechanical stability of a plated construct?
CANDIDATE
The literature is slightly confusing in how plate length and screw number affect the biomechanical stability of a plated construct. Concerns that the plated construct would not provide sufficient construct stiffness and fracture rigidity compared with fixation using shorter plates and more screws have not been realized.
source p. 514
EXAMINER
What are the biomechanical differences between an IM nail and a plate?
COMMENT
Start off by first mentioning the function of both an IM nail and a plate . A nail’s cross-section is round, resisting loads equally in all directions, where asa plate’s cross- section is rectangular, resisting greater loads in one plane compared to another (Figure 9.7). The primary function of the plate is to maintain alignment as an internal splint, and to create compression between the fracture ends such that bone can transfer some of the applied loads itself. A compression plate, tension bandora lag screw does this by generating compression across the fracture.
Figure 9.7
Figure 9.7Figure 9.7 Biomechanical comparison of plate vs. IM nail. A nail’s cross-section is usually round, resisting loads equally in all p. 515
Figure
Figurep. 514

Figure 9.6 Biomechanical differences between a plate and IM nail. Compared to an IM nail the bending moment (Force × Distance from force to implant) for a plate is greater due to the force being applied over a larger distance.

source p. 515
Figure
Figurep. 515

Figure 9.7 Biomechanical comparison of plate vs. IM nail. A nail’s cross-section is usually round, resisting loads equally in all directions. A plate’s cross-section is rectangular, resisting greater loads in one plane vs. the other.

EXAMINER
What factors contribute to the overall biomechanical profile of an IM nail?
CANDIDATE
Sorry? Several factors contribute to the overall biomechanical profile and resulting structural stiffness of an IM nail. These include: Material properties: most nails are made from either stainless steel or titanium. Cross-sectional shape . Nail diameter affects the bending and torsional rigidity of a nail. A larger diameter nail with the same cross-section is both stiffer and stronger than a smaller one. Diameter curves. Nails are contoured to accommodate IM curvature of long bones. Tibial nails have an 11° bend in the AP direction a t the junction of the upper third and lower two-thirds. Length and working length (see previous questions).
EXAMINER
What are the benefits of reamed nails?
CANDIDATE
Reaming allows the insertion of a lar ger-diameter nail that provides more rigidity inbending and torsion.
source p. 516

Reaming increases the contact area between the nail and cortical bone.

EXAMINER
You mentioned IM nails being curved. What is the reason for this?
CANDIDATE
IM nails are contoured to accommodate the curved intramedullary canal of a long bone.
EXAMINER
Anything else?
CANDIDATE
A straight nail if inserted into a curved intramedullary canal will bend and produce stresses
EXAMINER
Anything else?
CANDIDATE
A femoral nail is curved in an AP direction to conform to the curvature of the medullary canal.
EXAMINER
What happens when you insert a femoral nail into the medullary canal?
CANDIDATE
The nail must bend somewhat to fit the curve of the intramedullary canal. An axial insertional force is necessary to insert the nail and this insertional force is
EXAMINER
What about hoop stresses generated when a femoral nail is inserted into the medullary canal?
CANDIDATE
The insertional axial force applied generates hoop stresses within the bone. Excessively large hoop stresses can lead to fracture propagation.
EXAMINER
How do we reduce hoop stresses generated in the femur?
CANDIDATE
Avoid excessive force when impacting the nail in to the femur. Over-reaming the entry hole by 0.51 mm and using as lofted nail.
EXAMINER
Anything else?
CANDIDATE
Not sure.
EXAMINER
What about entry point?
CANDIDATE
Not sure. The most important factor affecting hoops tresses is femoral nail entry point. Avoid an excessive anterior or posterior entry point. This will generate excessively large hoop (expansion) stresses than can lead to a burst fracture of the femoral shaft.
source p. 517

IM nails have a straighter (larger) radius than the femoral canal with sometimes ami

source p. 518

Structured oral examination question 7#

source p. 519

Fracture healing

Fracture healing is a definite A-list topic. With a bit of revision and practice candidates should achieve a score 6 without too many difficulties.

1. Bone healing: types, types of stability, factors affecting it, cuting c ones diagram, different

2. Fracture healing, different types and stages.

Absolute versus relative stability options for fracture stabilization, fracture healing, factors affecting it evidence – did not know!).

EXAMINER
How do fractures heal?
CANDIDATE
Fractures can heal by either director primary fracture healing or secondary fracture healing. The answer needs expanding, as the next obvious question would be to give an example of primary fracture healing. The type of fracture healing that occurs depends on the mechanical stability present at the fracture site. The fracture fixation in this situation provides absolute stability. There is no motion a t the fracture site, and no callus is formed. Indirect or secondary fracture healing occurs with relative stability and movement at the fracture site.
EXAMINER
What do we mean by Perren’s strain theory?
CANDIDATE
Perren introduced the concept of strain in fracture healing. The strain of cortical bone until it breaks is low, around 2%, while granulation tissue has a high strain tolerance of 100%. Lamellar bone can tolerate up to 10% strain, and when this relative stability is present, the fracture heals with callus or secondary fracture healing.
source p. 520

Fracture healing will not occur when the strain at a fracture gap exceeds 10%.

EXAMINER
What actually happens at the fracture gap?
CANDIDATE
The same force applied to a wider gap filled with granulation tissue will, however , only deform this tissue and not cause any rupture.
EXAMINER
How does this influence the method of internal fixation you would chose to manage a fracture?
CANDIDATE
Applying Perren’s strain theory, a simple fracture type has ‘high strain’ and is best fixed by a method that produces absolute stability. A more comminuted fracture equates to a low-strain situation and can be managed with fixation that provides relative stability (bridging plate or IM nail).
EXAMINER
So, we can leave large gaps at the fracture site if we are aiming for relative stability?
CANDIDATE
Small gaps can be left a t the fracture site incomplex fractures managed with relative stability and are usually tolerated.
EXAMINER
How big a fracture gap?
CANDIDATE
If you have gone for absolute stability, then any persistent fracture gap should be avoided as this may predispose to non-union.
EXAMINER
What do we mean by a stress riser?
CANDIDATE
A stress riser (concentrator) is a region of an object in which stresses are higher than in the surrounding material.
EXAMINER
What causes crack growth?
CANDIDATE
Crack growth is heightened by stress corrosion, poor bone-to-bone contact at the fracture and if apa tien t has a large body mass.
EXAMINER
What do we mean by stress corrosion?
CANDIDATE
Stress corrosion combines the effects of local growth of the crack resulting from cyclic loading with galvanic corrosion.
EXAMINER
What is galvanic corrosion?
source p. 521
CANDIDATE
Galvanic corrosion can weaken the properties of a plate and screws, causing failure of fracture fixation and possible pain ands welling of the surrounding tissue.
EXAMINER
That’s with a plate and screws, but we are discussing an isolated stress concentration propagating and expanding on a plate leading to fatigue failure.
CANDIDATE
In a fixed fracture, the dissimilar materials are the surface of the plate (e.g. stainless steel), which creates an oxide surface coating , and the same material exposed by the fatigue cr ack that has not yet developed the oxide film. The conductive fluid is saline found in the surrounding tissues.
EXAMINER
Why do we tap before screw insertion?
CANDIDATE
With a pre-tapped hole, around 65% of the torque goes to produce compression and 35% to overcome the friction associated with driving the screw. When the hole is not tapped, only about 5% of the torque is used to produce compression, the rest going to overcome friction and to cut threads in bone.
EXAMINER
So why do we sometimes a void tapping in cancellous bone?
CANDIDATE
In cancellous bone screw pull-out can become an issue, particularly in osteoporotic bone. Tapping reduces strength in cancellous bone in that running the tap in and out
EXAMINER
What factors affect screw pull-out?
COMMENT
This is a classic predictable screw exam question Candidates need to have rehearsed and run through their answer beforehand.
EXAMINER
Why is it important to do a final check and tighten all screws at the end of fracture fixation?
CANDIDATE
A screw holds the plate against bone partly by frictional contact, which depends on the frictional force generated between the undersurface of the plate and the bone. If any sliding occurs between the plate and the bone, the bending load will be transferred
source p. 522

Structured oral examination question 8#

source p. 523

Fracture healing

EXAMINER
How does fracture healing occur?
CANDIDATE
Fracture healing can occur by primary or secondary bone healing.
EXAMINER
What is primary bone healing?
CANDIDATE
This requires close anatomical reduction with minimal movement at the fracture site (< 2% strain). Remodelling then occurs across the fracture site, with cuting c ones passing across the fracture site.
EXAMINER
What is gap healing?
CANDIDATE
This is a type of primary bone healing.
EXAMINER
And?
CANDIDATE
In this process the fracture site is primarily filled by lamellar bone oriented perpendicular to the long axis, requiring a secondary osteonal reconstruction, unlike the process of contact healing.
EXAMINER
What is contact healing?
CANDIDATE
If the gap between bone ends isless than 0.01 mm and interfragmentary strain isless than 2%, the fracture unites by so-called contact healing. The tips of the cuting c ones consist of osteoclasts which cross the fracture line, generating longitudinal cavities a t a rate of 50–100 μm/day. The answer is a bit out of sync as usually contact and then gap healing is described.
EXAMINER
Can you draw a cuting c one for me, please?
COMMENT
See Chapter 20.
source p. 524
EXAMINER
What is secondary bone healing?
CANDIDATE
Secondary healing (by callus) requires some motion a t the fracture site (> 2% but < 10%). It consists of both endochondral and intramembranous bone healing. The strength of the healing fracture does not necessarily correlate with its stiffness.
EXAMINER
What are the stages of secondary fracture healing by callus?
CANDIDATE
The stages of fracture healing include: Stage 1: First week. Proinflammatory cytokines (including IL-1 and IL-6 and tumour necrosing factor α), and peptide signal molecules (including BMP s, TGF-β and PDGF) recruit inflammatory cells and promote angiogenesis. The haematoma coagulates in between and around the fracture ends, and within the medulla forming a template for callus formation Granulation tissue forms. The acute inflammatory response peaks within the first 24 hand is complete after 7 days. Stage 2: 1 week to 1 month. In this stage, fibrous tissue, cartilage and woven bone form Chondroblasts and fibroblasts differentiate and form collagen (mainly type II) and fibrous tissue. Stage 3: 1–4 months. Stage 4: Remodelling – several years.
source p. 525

Structured oral examination question 9#

source p. 526

Screws3

Introduction

This material is asked in ST3 interviews and trauma meetings and covered in the mandatory AO Basic Principles of Fracture Management course, and also lots of FRCS

(Tr & Orth) revision textbook model answers or on websites.

The examiners usually probe and ask less-obvious questions if candidates have done well and are heading for a good pass (score 7/8). The other alternative is probing because the examiners had been expecting a better performance with greater detail.

We present an answer outline to be used as a guide only. This is a rather dull topic in print, only really coming to

A dry run through of the topic is definitely more useful than multiplet extbook re-reads of the topic.

COMMENT
Candidates may be asked to draw a screw out or be shown a laminated diagram of a screw and asked to describe the various screw design features (Figures 9.8 and 9.9). Be prepared for both scenarios.
EXAMINER
Can you describe the different parts of the screw and their function?
CANDIDATE
Figure
Figurep. 526

Figure 9.8 Candidate drawing of a screw.

source p. 527
Figure
Figurep. 527

Figure 9.9 Screw terms.

Head

This prevents sinking of the screw into the bone and provides a connection for a screwdriver.

The main slot designs (recess types) for a screwdriver are (1) single slot, (2) cruciate head, (3) Philips,

(4) recessed hexagonal head (hex head) and (5) Torx-6 stardriver (Figure 9.10).

Figure 9.10
Figure 9.10Figure 9.10 Slot for screwdriver.p. 527

A hexagonal head has six points of contact to increase torque, avoid slip and improve directional control.

Figure
Figurep. 527

Figure 9.10 Slot for screwdriver.

Countersink

The countersink is the undersurface of the head and is either conical or hemispherical.

Runout

Transitional area between shaft and thread. Site of a stress riser and where a screw may break if incorrectly inserted.

source p. 528

Shaft

Smooth link between head and thread. Almost not present in a standard cortical screw.

Thread geometry

This provides a wide surface for pulling and litile frictional resistance on the underside.

Thread pitch

With each full turn the screw advances by a distance equal to the distance between the threads.

Cortical screws have a fine pitch and therefore a greater number of threads. Cancellous screws have a coarse pitch.

A fine-pitched screw moves a smaller distance linearly for a given angular rotation, offers greater mechanical

Thread depth

Thread depth is half the difference between thread diameter and core diameter. The thread depth determines the amount of contact with bone that inturn determines the resistance to pull-out.

Thread shape

The shape of thread may be V-thread (more stress at sharp corner), but iress

Lead

The lead is the linear distance travelled by a screw for one complete (360°) turn of the screw. If a screw is single-threaded, the lead is the same as the pitch.

Diameters

Core diameter: narrowest diameter in the thread section. Solid section from which the threads project outwards. Also, a weak part of a screw.

Sha diameḁter: diameter of shaft where there is no thread.

Outer or Thread diameter: the maximal thread width. The larger the outer diameter, the greater the resistance to pull-out.

source p. 529

Flutes

Channels that provide a route for removal swarf (bone debris).

Tip

Several different designs are available. The tip can be:

Non-self-tapping screw: smooth, conical tip. Needs pr e-drilling of a pilot hole and then use of a tap to create a channel/thread for insertion.

Self-tapping: needs pre-drilling of a pilot hole, but has cuting flutes for creating its own thread/channel

Self-drilling and self-tapping: tip will ma kea drill hole and will cut the channel for the thread.

Corkscrew tip: used in cancellous screws where the tip clears the pre-drilled hole.

COMMENT
Candidates may be stopped at any stage to be more closely questioned on a particular aspect of screw design.
EXAMINER
What is the biomechanical definition of a screw?
CANDIDATE
There are several definitions. A screw is a mechanical device that converts a rotational movement (torque) into a linear movement (translation).
EXAMINER
What do we mean by a screw’s purchase?
CANDIDATE
A screw’s hold in bone is referred to as purchase.
EXAMINER
What do we mean by a screw pull-out strength?
CANDIDATE
The axial force required to remove a screw is referred to as its pull-out strength.
EXAMINER
How can you maximize pull-out strength4?
CANDIDATE
The pull-out strength of a screw can be increased by increasing the contact surface area (interface) between screw threads and bone. This effectively increases the width of the threads. Enough for a 6 pass.
source p. 530

Increasing the number of threads engaged in the bone cortex (increased cortex thickness, bi cortical fixation).

Use a locking screw.

The ‘finer’ the pitch and the more turns the surgeon needs to make to insert the screw and the more turns of the spiral thread engage in a given depth of cortex.

EXAMINER
What happens if the pitchis too small?
CANDIDATE
If the pitchis too small there is insufficient bone between individual threads.
EXAMINER
How does the use of a locking screw maximize pull-out strength?
CANDIDATE
A screw used in a locking plate requires resistance to bending both at the junction between the plate and screw and along the length of the screw. A locking screw as such has a relatively larger core diameter in relation to the thread diameter. This osteosynthesis method is much sturdier compared to sequential pull-out of conventional screws.
EXAMINER
What surgeon factors can reduce screw pull-out strength?
CANDIDATE
Making too large a pilot hole. Wobbling of the screwdriver handle during insertion. Poor technique or technical mistake.
source p. 531

Structured oral examination question 10#

A laminated photograph showing different types of screws (usually cancellous, cortical or cannulated) may be shown to a candidate.

With the standardized viva format the days of candidates being handed over a screw to describe are over.

EXAMINER
Describe the different types of screw.
CANDIDATE
Cortical and cancellous. The main differences relate to: Pitch. Cancellous screws have a larger pitch, greater thread depth and a smaller number of threads. Cancellous screw tips are designed as a tapering spiral. Higher ratio in acor tical screw. Thread depth determines whether a screw is cancellous or cortical. Ratio of inner (c ore) diameter to outer (thread) for a 4.5mm cortical screw is 3/4.5 (66.7%) and for a 4 mm cancellous screw is 1.9/4 (47.5%) ~ 2/3rds to 1/2. Fully or partially threaded screw. A locking screw has threads on the head to allow locking into plates and provide angular stability of the plate screw construct, increasing the pull-out strength of the screw. The hollow core weakens the screw, although clinically this is not often a problem. Guide wire allows radiological check prior to screw insertion.
EXAMINER
How do the design features of a particular screw relate to its function?
CANDIDATE
source p. 532

Cortical screw: acor tical screw is designed to gain maximal purchase in the bone cortices. Cortical bone is usually dense but has limited thickness.

Cancellous screw: this screw is designed to gain purchase in cancellous bone, most commonly the metaphyses of long bones. Cancellous bone isless dense and spread out compared to cortical bone and to gain maximum purchase cancellous screws have wider threads and larger pitch.

The locking screw locks into the plate. The plate/screw construct is more rigid than a non-locking construct and provides greater implant stability.

Cannulated screw: this has a canal through the central core in which a guide wire can be used to guide the position of the screw.

Locking screw (bolt). This is designed to control torsional and axial loads. A large core diameter (strength of screw

EXAMINER
What is the technique of lag screw fixation across a fracture site5?
CANDIDATE
Drilling large lag (gliding) hole (near cortex). Drilling small (threaded) hole (far cortex). Countersinking. Measuring. Taping the far cortex with a protective tap sleeve. Need direction and wobble control. Insertion of screw. Reduction forceps should be removed just before final tightening of the screw. Be sure of your order. For example, if measuring takes place before countersinking then the length of the screw will be too long.
EXAMINER
What about fracture reduction?
source p. 533
CANDIDATE
Normally, the fracture fragments should be reduced before the near cortex is drilled.
EXAMINER
What do you mean by countersinking a screw?
CANDIDATE
When a screw is used without a plate, a countersink hole is created to reduce the risk of fracture as the screw is tightened.
EXAMINER
What else?
CANDIDATE
Failure to countersink can result in very high stresses at the screw head/bone interface, causing microfractures, leading to screw loosening.
EXAMINER
What else?
CANDIDATE
Failure to perform proper countersinking causes an eccentric loading and lessens the degree of compression.
EXAMINER
So, what about a small fragment cortical screw, what size is this?
CANDIDATE
A small fragment screw has a thread diameter of 3.5 mm and a core diameter of 2.5 mm.
EXAMINER
What about drill sizes for a lag screw?
CANDIDATE
3.5-mm drillbit (silver) for the gliding hole and 2.5-mm drillbit (gold) for the thread hole.
EXAMINER
Is that for a large or small fragment cortical screw?
CANDIDATE
Small cortical screw. For a small cortical lag screw the near cortex is drilled with a 3.5-mm drill before the far cortex is drilled with a 2.5-mm
EXAMINER
What about a large fragment screw when it is used as a lag screw?
CANDIDATE
For a large fragment screw this has a thread diameter of 4.5-mm and a core diameter of 3.1- mm. This is score 5/score 6 material. Candidates are not scoring any marks.
EXAMINER
What else?
CANDIDATE
We use a 4.5-mm drillbit for the gliding hole and a 3.2-mm pilot drillbit for the threaded hole.
EXAMINER
What size of tap do we use?
CANDIDATE
The tap is 3.5 mm.
source p. 534
COMMENT
If a candidate mentions using a 4.5-mm drill and a 3.5-mm tap they are heading for a poor fail (score 4) as they don’t understand the principles of lag screw fixation.
EXAMINER
How do we measure the depth of the screw tract?
CANDIDATE
We use a depth gauge.
EXAMINER
How?
CANDIDATE
It is important to engage the hook of the depth gauge against the obtuse edge of the exit hole, not the acute angled edge, otherwise the screw depth will be incorrect.
EXAMINER
What about a mini fragment set?
CANDIDATE
These contain cortical screws of size 1.5 mm and 2.0 mm.
EXAMINER
What else?
CANDIDATE
The 1.5-mm screws are used to fix phalangeal fractures while the 2.0-mm screws are used to fix metacarpal fractures.
EXAMINER
Drillbit for gliding hole and threaded hole and tap for a 1.5-mm cortical screw.
CANDIDATE
I don’t think they are used as a lag screw.
EXAMINER
They can be used as a lag screw if needed.
COMMENT
For a 2-mm screw it is 2.0 mm for a gliding hole, 1.5 mm for a threaded hole and a 2-mm tap.
EXAMINER
What are the principles of the lag screw technique?
CANDIDATE
It is a technique, not a type of screw. Any screw can function as a lag screw. It provides interfragmentary compression. The lag screw should compress fracture fragments together.
EXAMINER
What are the conditions for interfragmentary compression?
CANDIDATE
The screw must glide through the near cortex.
source p. 535

Threads hold only in the far cortex.

Screw head should stop at the near cortex.

The maximum compression occurs at 90° to the fracture.

EXAMINER
When does the lag screw principle fail?
CANDIDATE
Sorry, I am not sure what you mean. Lag screws should not be used in comminuted fractures. They should be inserted perpendicular to the fracture plane to generate the greatest interfragmental compression and reduce the risk of fracture displacement.
EXAMINER
What are the functions of a scr ew6?
CANDIDATE
To produce interfragmentary compression. To attach implants to bone, producing angular stability. To lock an intramedullary nail to the cortices. AO teaching.
EXAMINER
OK. Can you name me the different types of screw function?
CANDIDATE
I am not sure. Plate screw: preload and friction is applied to create a force between the plate and the bone. Lag compression screw (see above). Position screw: holds anatomical parts incorrect relation to each other without compression, i.e. thread hole only, no glide. For example, syndesmosis screw.
source p. 536

Anchor screw: a point of fixation used to anchor a wire loop or strong suture. For example, K-wire fixation of medial malleolus fracture.

Push pull screw: a temporary point of fixation used to reduce a fracture by distraction and/or compression.

Reduction screw: a conventional screw is used through a plate to pull fracture fragments

Pollar: screw is used as a fulcrum to redirect/guide an IM nail.

Candidates may be quizzed in more detail on each specific function.

Figure
Figurep. 536

Figure 9.11 Screws, drills, bits and taps.

source p. 537

Structured oral examination question 11#

source p. 538

Screw

The candidate is shown a picture of acor tical screw. What is a screw? What are the parts of the screw?

Why are there different thread diameters? How do you use a lag screw? Why do some screws now have threads in their heads?

COMMENT
Similar question to previous ones, but with a few different twists along the way.
EXAMINER
What is a screw?
CANDIDATE
A screw is a device which converts rotational forces into linear motion [A O definition].
EXAMINER
What are the parts of a screw?
CANDIDATE
A screw has four main functional components. Head. Shaft. Thread. Tip. This is your basic score 5/6 answer. Most candidates should aim to give a bit more detail in their answer to make sure of scoring at least a 6.
EXAMINER
What is the difference between thread diameter and thread depth?
CANDIDATE
The thread depth determines the amount of contact with the bones, which inturn determines the resistance to pull-out. The size of tap is equal to the thread diameter.
EXAMINER
How do you use a lag screw7?
COMMENT
A slightly ambiguous question Possibly asking about what fractures are best suited for lag screw fixation
EXAMINER
Why do some screws now have threads in their heads?
CANDIDATE
These are locking screws. They increase screw pull-out strength and prevent sequential pull- out failure of a plate.
source p. 539

Structured oral examination question 12#

source p. 540

Lag screw

Lag screw, principles, how plates work, how nails work. Types of screw. Draw cross-section of a washer. How does a washer work?

EXAMINER
How do plates work?
CANDIDATE
A bone plate transmits forces from one end of the bone to the other bypassing and therefore protecting the area of fracture. It also holds the fracture ends together maintaining alignment while the facture heals.
EXAMINER
What factors determine the success of a bone–plate fixation construct?
CANDIDATE
Cyclical forces above the fatigue limit will eventually lead to plate failure if the fracture does not heal. A race against time for fracture healing versus hardware failure. Locking screws fail en masse. Construct-placement of plate and direction of load. Compression between fragments: always attempt to apply a plate on the tension side of the bone and under compression.
EXAMINER
What determines the strength of a plate?
CANDIDATE
BH3/12 B = base, H = height. Bending stiffness is proportional to the thickness (h) of the plate to the third power.
EXAMINER
Why do we use a washer?
CANDIDATE
Washers spread the load applied by the head on the underlying cortex and are used to prevent the screw head from breaking through a thin cortex [AO]. The y are mainly used in metaphyseal bone or if the bone is osteoporotic.
source p. 541
EXAMINER
Draw a cross-section of a washer.
COMMENT
A washer has two sides, a flat side and a concave side. The flat side of the washer rests on the
source p. 542

Structured oral examination question 13#

source p. 543

Design features of a screw

You are given a new screw from a rep. How would you appraise it? What would determine if YOU would consider using it or not?

You are given two types of self-tapping screws (one normal, one reverse-cuting as well as

You are given DC Sand DHS. What are these implants? What are the principles and design specifications of a compression plate?

EXAMINER
You have been given a new screw from a company representative How would you appraise it? What would determine if YOU would consider using it or not?
COMMENT
This is similar to the ‘given a new plate by a repand asked to evaluate’. This question is designed to test higher-order thinking. It is one level above a candidate talking through the various functional parts of a screw. What is the material of the screw titanium, stainless steel, bioabsorbable)? Titanium: high tensile and yield strengths, reduced stiffness, increased biocompatibility , Young’s modulus of elasticity closer to bone, diminished stress shielding MRI compatible, superior strength under the high cycle repeated load stresses. Titanium and titanium alloys are not notch-sensitiv e, which means that stress raisers have minimal effects on the mechanical properties of titanium implants. Bioabsorbable: radiolucent, eliminates the need for hardware removal, reduced stress-shielding and allows a gradual load transfer to a healing fracture. Candidates may have a freehand into what screw function they can discuss or be pushed towards one particular direction.

If a screw is not self-tapping it will generally be necessary to use a tap to cut a thread into the bone before screw insertion.

CANDIDATE
I would want to prevent screw failure and need to consider the following factors. Tensile strength (resistance to bending): this is directly proportional to the square of its core diameter – core diameter2. Torsional strength: proportional to the cube of its core diameter – core diameter3. It is affected by the density of the bone beneath the screw threads. A hemispherical undersurface is generally preferred because it allows a screw to be angulated in all directions within a washer or the screw hole of a plate while maintaining concentric contact between the screw and side of the plate. Score 8: The pull-out strength of a screw increases with increasing screw length, thread diameter, thread depth and bone strength. F = S × (L × π × D) × TSF F = pullout strengthS = ultimate shear strength of bone L = screw length D thread diameter The thread shape factor is defined as 0.5 plus the ratio of thread depth to thread pitch multiplied by a constant TSF = 05 + thread depth/thread pitch × K (constant)
source p. 545

The TS Fand thus screw holding strength increase whenever the thread depth becomes larger (larger threads and smaller root diameter).

EXAMINER
Given two types of self-tapping screws (1 normal, one reverse-cuting aswell as self-tapping) – describe these implants. Why would you use a reverse self-cuting screw?
CANDIDATE
Self-tapping screws are produced with sharp cuting flutes at the leading end of the threaded portion of the screw. The flutes are milled into the thread blank. The flutes cut through bone and facilitate screw insertion. These are called reverse-cuting flutes which allow the thread to cut its way out of the bone after fracture healing.
EXAMINER
Can you give me an example of when to use a reverse self-cuting screw?
CANDIDATE
Reverse self-cuting screws are used to make screw removal easier. The screws are usually self-tapping screws with reverse-cuting flutes .
EXAMINER
Given (shown aDCS and DHS implant. What are these implants? Describe their differences. How would you apply them (exactly, with the order of screw placement and why)? What are the principles and design specifications of a compression plate?
CANDIDATE
A DCS plate was initially designed for fixation of distal femoral fractures but can also be used to fix proximal femoral fracture sADHS implant is the ‘gold standard’ for intertrochanteric fracture treatment. The main difference between these two implants is the angle of the lag screw with respect to the plate (Figure 9.12). Because the DCS plate has a 95° barrel angle, it does not allow for controlled compression. Using a 135° DHS plate to treat long oblique subtrochanteric fractures does not always allow fracture compression. With the 95° DCS plate stable fixation can be achieved by lagging the fracture through the plate because controlled collapse is not likely to occur.
Figure 9.12
Figure 9.12Figure 9.12 DCS plate for stable subtrochanteric fractures.p. 547
source p. 546

Two 6.5-mm cancellous screws are inserted after lag screw insertion and seating of the plate

(Figure 9.13).

Figure 9.13
Figure 9.13Figure 9.13 Insertion of two 6.5-mm cancellous bone screws through the proximal round holes of the DCS plate.p. 547
EXAMINER
What size of drill do we use?
CANDIDATE
We drill a hole in the near cortex with a 4.5-mm drillbit. The 4.5/3.2 drill sleeve is fully seated into the plate hole and a 3.2-mm drillbit is used to drill into the far cortex.
EXAMINER
What do you mean by the drillbit gliding along the calcar?
CANDIDATE
Sorry, I am not sure. If a lag screw technique isn’t used the 3.2-mm drillbit will strike the endosteal aspect of the calcar obliquely and be deflected up the neck, where it may break. Th eDHS plate is fixed to the femur using 4.5-mm cortical screws.
EXAMINER
When do we use a compression screw?
CANDIDATE
It allows further fracture impaction. It is useful in unstable fractures to prevent disengagement of the lag screw from the plate barrel.
EXAMINER
Are there any concerns with using a compression screw?
CANDIDATE
A compression screw can cause stripping of the lag screw thread in porotic bone. A void excessive force and remove the compression screw after use.
EXAMINER
Why?
CANDIDATE
I am not sure. A recent paper suggested retaining the compression screw as it helped to lessen mechanical failure of
source p. 547
Figure
Figurep. 547

Figure 9.12 DCS plate for stable subtrochanteric fractures.

Figure
Figurep. 547

Figure 9.13 Insertion of two 6.5-mm cancellous bone screws through the proximal round holes of the DCS plate.

source p. 548

Structured oral examination question 14#

source p. 549

Design features of a plate

COMMENT
Plate design needs a bit of thought and pre-planning because if you are hit blind with this topic in a viva you may struggle and not respond well to questions. It gives the examiners the opportunity to focus in and test your knowledge on various subsections of biomechanics.
EXAMINER
Design the perfect plate.
CANDIDATE
Score 4: I use a z plate because I know it well, the company sales representative is very supportive, we use this plate in our hospital and the company have been very competiv e in their pricing. This question is about principles of plate design and is used to test candidates for higher- order thinking skills. Stay clear of mentioning specific company implants.9 This is in contrast to referring to a cemented Exeter hip implant in a viva. This widely used implant isO DEP 10 A rated with 30 years survivorship results and most trainees are familiar with the kit. These protocols are usually decided through an appropriate local commift ee using a best evidence-based approach.
source p. 550

Constructing an answer

Prepare a simple sentence and then divide your answer into various different headings and then work on the headings.

The design of my implant would require consideration of many factors which would include

1. Material properties

Candidates may end up discussing:

Youngs modulus.

Yield point.

Toughness.

Hardness.

Material properties are independent of shape.

It should be acceptably priced, have corrosion resistance and provide adequate ductility , toughness and hardness.

2. Structural properties

Bending stiffness.

Torsional stiffness.

Axial stiffness.

3. Interface fixation

Locking vs. non-locking plate.

4. Modality of use

Primary healing vs. secondary healing.

Anatomical reduction versus alignment.

Rigid versus relative fixation.

Load-sharing vs. load-bearing.

Combination.

Straight locking vs. variable angle.

source p. 551

Notes

1. Orthobullets, Ryan Eggers, Comment on structural properties.

2. The keywords are ‘a constant volume of material for a fixed length.’

Take hold of a screw and practise out loud naming its various components until flawless.

4. The examiners may stop a candidate half-way through their description of a screw and ask this question.

5. Six steps in the lag screw technique.

6. The examiners may drill down for more detail onto a particular function.

7. The question is abit clums y. Better phrased as when to use a lag screw rather than how to use a lag screw.

8. Chang C-W, Chen Y-N, Li C-T, Peng Y-T, Chang C-H. Med Eng Phys. 2015;37(12):1174–1179.

9. Possibly NCB periprosthetic Zimmer system, as its use is very versatile for difficult complex periprosthetic femoral fractures.

figure